Prouduct

Laser Particle Size Analyzer for Soil Powder Cement Medicine

Laboratory Analysis by Laser Particle Size Analyzer for Soil Powder Cement Medicine KR-2076 automatic laser particle size analyzer is an intelligent laser particle size analyzer. It uses LSI to i

  • Model: KR-2076

Laboratory Analysis by Laser Particle Size Analyzer for Soil Powder Cement Medicine

 

KR-2076 automatic laser particle size analyzer is an intelligent laser particle size analyzer. It uses LSI to integrate the dispersing system, ultrasonic system, circulating system, water feeding system, water draining system, optical system and sampling system. A standard SOP controls the fully automatic operation. Such design considerably reduces the workload and error during test.

 Kolery Analysis Instruments

Applications:

 

Abrasives, Adhesives, Agrochemical, Barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble, Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Diatomite, Dolomite, Emulsion, Environmental, Explosives, Ferrite, Fluorescent, Fluorite, Food & Beverage, Food Additive, Graphite, Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals, Oxides, Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers, Quartz, Refractory, Resins, Silica, Slurries,Soil Sediments, Sulfur, Synthetics, Talc, Toners, Tourmaline, Wollastonite, Zeolite, Zirconium Silicate in micron range.

 

Features:

 

1.2.1 Special Coating: External (corrosion resistant) and internal (anti-reflective) coatings effectively shield the interference by unwanted light and reflecting walls. Special coating protects the laser diffraction and improves the analyzer performance. 

1.2.2 Robust Light Source: Excellent monochromatic laser diode works for at least 25,000 hours. No work, no loss. Monochrome improves the accuracy and long lifetime extends the working life of laser particle size analyzer. A novel design integrates Fourier lens into the holder of laser diode which optimizes the light path alignment. 

1.2.3 Stable Optical Bench: All major optical assemblies such as laser, cell holder and detection system are firmly fixed on one cast steel optical bench. This patented design uproots light path deviation, one of the major technical problems in the industry of particle size analysis. 

1.2.4 Sensitive Photocells: High-resolution photocells make AS-2011 much more sensitive than any other particle size analyzer. Detection system array effectively captures the scattered light thus ensures the authenticity and accuracy of particle size characterization. 

1.2.5 High-Speed Circuit Boards: Circuit boards of serial port, filtering, amplification and data transmit & process have a considerable advantage in speed over traditional ones. They work with new algorism to give a satisfactory measurement time.

1.2.6 Versatile Small (Volume) Cell Assembly: The small cell assembly has found wide applications because of its very small fault rate and high reliability. Corrosion-resistant small cell can either hold water or other mediums. Micro silent agitator fully stirs up the suspension and improves the accuracy and repeatability

1.2.7 Optional AS20 Dispersing Unit: AS20 Dispersing Unit integrates functions of dispersing, agitating and circulating. It effectively suspends high-density particles in water to achieve a better accuracy. The panel of AS20 is simple and easy to use.

1.2.8 Ingenious Cell Holder: Patented cell holder makes the shift between small cell and flow cell assembly easy and safe.

1.2.9 Advanced Mie Scattering: AS-2011 laser particle size analysis system adopts the most advanced principle of Mie Scattering and gives the micron particles a scientific and objective particle size analysis.

1.2.10 Accurate & Fast Algorism: A new algorism has been designed which will be able to obtain the accurate results and greatly reduce the measurement time.

1.2.11 Flexible Parameters: In order to improve the correlation capability of AS-2011 with other laser particle size analyzers, AimSizer develops advanced and flexible parameters to make AS-2011 the preferred substitute of world renowned LPSAs. These parameters can provide users with the acceptable correlation results.

1.2.12 Safe Log on: User can log on particle sizing software in two ways: Administrator or Operator, only Administrator is authorized to modify the major settings of particle size analysis system, which greatly improves the security and stability.

1.2.13 Automatic Measurement: The automation starts with automatic error detecting on background and light path, and then size analysis is carried out automatically. In less than 60 seconds size distribution is displayed on the computer screen ready for exporting to Excel or print.

1.2.14 Comprehensive Analysis report: The result analysis report includes typical values, size distribution curve/histogram as well as table of size distribution in order to compare with other results respectively. User is also allowed to edit and customize the report.

1.2.15 Authoritative Validation & Traceability: Aimsizer validate each unit by measuring stable Certified Reference Material CRM SB2005, which ensures the performance of each analyzer and optimizes the traceability. The results obtained must agree with the standard values before export.

1.2.16 Satisfying Accuracy & Repeatability: More than meeting the requirement of ISO13320-1 on accuracy and repeatability (<3%), AS-2011 further optimizes the reproducibillity to a new level (<3%)


1.1.1  Size range: 0.1-500um 

1.1.2  Test time: less than 1 minute (sample dispersion not counted) 

1.1.3  Test method: liquid (dilute sample and add suspension to the sample cell for test) 

1.1.4  Obscuration: 15-60(energy of diffracted light and the corresponding percentage concentration is about 0.01‰-6‰, it involves the refractive index of the sample). 

1.1.5  Output results: cumulative size distribution (data and graph), differential size distribution (data and histogram), median (D50), WMD (weight mean diameter), specific surface area (SSA) and typical results for                   specific size etc. 

1.1.6  Accuracy and repeatability: <1 %( deviation measuring certified reference powder).

1.1.7  Power AC 220V±10% 50Hz or 60Hz Power 80W

1.1.8  Light source: Semiconductor laser Wave 635nm Power 3mw

1.1.9  Computer interface: standard RS-232 serial port 

1.1.10  Operating system: Windows

1.1.11  Printer: compatible with Windows